Generator Sizing Calculator
Minimum generator size for a set of household or site loads.
Reviewed by the Calculation Machine team · Updated 24 October 2026 · How we check our maths
Your values
ⓘ Live results
- Minimum generator size
- 7,150 W
- Minimum generator size
- 7.15 kW
- Total running load
- 3,500 W
Quick answer
A generator must cover all running watts plus the extra starting surge of the largest motor load, plus a safety margin: size = (running total + largest surge − that load's running watts) × (1 + margin). With 3,500 W running, a 4,500 W surge from a 1,500 W load and 10% margin, you need at least 7,150 W (7.15 kW).
What the Generator Sizing calculator does
This calculator gives the minimum generator output for a set of loads you want to run at once. You enter the total running watts, the starting (surge) watts of the single biggest motor load and that load's own running watts, plus a safety margin. The result is the continuous rating to look for on a portable, inverter or standby generator.
Homeowners use it for power-cut planning — fridge, freezer, sump pump, furnace blower, lights — and contractors use it for tools on job sites. Motors in compressors, pumps and air conditioners draw several times their running power for a second or two when they start, and that brief surge is usually what decides the generator size.
The method assumes you start the largest motor last, after the other loads are running, and that only one big motor starts at a time. If several motors may start together, add their surges. For loads on a three-phase supply, the three-phase power calculator converts amps to kW.
The formula
Size (W) = (P_run + max(0, P_surge − P_surgeRun)) × (1 + m ÷ 100)
| Symbol | Meaning | Unit |
|---|---|---|
| P_run | Sum of running watts of everything you will run at the same time | W |
| P_surge | Starting watts of the single largest motor load | W |
| P_surgeRun | Running watts of that same load (already counted in P_run) | W |
| m | Safety margin for future loads, aging and derating | % |
This is the sizing method generator manufacturers use in their wattage worksheets: running total plus the largest additional starting load. Compare the result with the generator's running (rated) watts, not its peak or starting watts. Output falls with altitude and high ambient temperature; manufacturers' manuals give the derating, commonly a few percent per 1,000 ft of elevation. For a standby system connected to house wiring, NFPA 70 (NEC) Article 702 applies and a transfer switch is required.
Worked examples
Essential home loads in a power cut
Fridge, freezer, lights, internet and a furnace blower total 3,500 W running; a well pump that runs at 1,500 W surges to 4,500 W.
Inputs
- Total running watts3500 W
- Largest single surge watts4500 W
- That load's own running watts1500 W
- Safety margin10 %
Result
- Minimum generator size7,150 W
- Minimum generator size7.15 kW
- Total running load3,500 W
At least 7,150 W, so a generator rated around 7,500 W running fits. Starting the well pump last, after the other loads are stable, is what makes this size work.
Small job site
A contractor runs lights, a radio, a battery charger and a 700 W compressor (1,800 W running in total); the compressor surges to 2,200 W. A 20% margin allows for extra tools.
Inputs
- Total running watts1800 W
- Largest single surge watts2200 W
- That load's own running watts700 W
- Safety margin20 %
Result
- Minimum generator size3,960 W
- Minimum generator size3.96 kW
- Total running load1,800 W
About 3,960 W, so a 4,000 W-class portable just covers it. Adding a circular saw later would need a bigger unit or careful timing of starts.
Whole-house standby with central AC
A house with 9,000 W of running load including a 2,500 W central air conditioner that surges to 7,500 W on start.
Inputs
- Total running watts9000 W
- Largest single surge watts7500 W
- That load's own running watts2500 W
- Safety margin10 %
Result
- Minimum generator size15,400 W
- Minimum generator size15.4 kW
- Total running load9,000 W
About 15.4 kW. A soft-start kit on the AC compressor can cut its surge substantially, which may allow a smaller standby generator; an electrician should confirm the final sizing.
Typical running and starting watts
Ranges are typical household figures. Always check the nameplate: running watts ≈ volts × amps, and motor nameplates may list locked-rotor amps (LRA) for starting current. Resistive loads like heaters have no meaningful surge.
| Appliance | Running watts | Starting watts |
|---|---|---|
| Refrigerator or chest freezer | 100–800 | Up to about 2,200 |
| Sump pump, 1/2 hp | About 1,000 | 2,000–2,500 |
| Well pump, 1/2–1 hp | 1,000–2,000 | 2,000–4,000+ |
| Furnace blower fan | 300–900 | Up to about 2× running |
| Window AC, 10,000 BTU | About 1,000–1,200 | About 2–3× running |
| Space heater | 1,500 | 1,500 (no surge) |
| Electric water heater | 4,000–4,500 | Same as running |
| Microwave, 1,000 W | About 1,500 drawn | No large surge |
| LED lighting, whole floor | 50–200 | Same as running |
Common generator sizing mistakes
- Comparing with peak watts. Generators advertise a higher starting or peak figure; your result must be within the running rating.
- Adding every surge. Surges last a second or two, so only the biggest one usually needs headroom — unless two motors (say a well pump and AC) can kick in together.
- Forgetting 240 V loads. Well pumps, central AC and electric ranges often need a generator with a 240 V outlet or a standby unit, not just more watts.
- Ignoring fuel and run time. A generator running at 50–75% of its rating is usually most fuel-efficient; one sized exactly to the peak spends most of its time lightly loaded or overloaded.
- Sensitive electronics. Inverter generators produce cleaner power for computers and modern appliances with electronic controls.
Safety and connection to your home
Portable generators produce carbon monoxide: the US Consumer Product Safety Commission advises running them only outdoors and far from doors, windows and vents, never in a garage, and fitting battery CO alarms indoors. Never back-feed a house through an outlet with a double-ended cord — it can energize utility lines and kill line workers. Use a transfer switch or interlock installed by a licensed electrician. For a battery-and-solar alternative, compare with the solar panel calculator and battery runtime calculator.
How to use the Generator Sizing Calculator
- 1List everything you will run at the same time and add up their running watts (volts × amps from each nameplate).
- 2Find the load with the largest starting surge — usually a well pump, AC or compressor — and enter its starting watts.
- 3Enter that same load's running watts so the calculator only adds its extra surge on top of the running total.
- 4Set a safety margin (10–25% is typical) and compare the result with generators' running, not peak, rating.
Frequently asked questions
What size generator do I need to run a house?
Essential loads (fridge, freezer, lights, sump or well pump, furnace fan) typically need about 5,000–8,000 W. Running central air and electric cooking as well often takes 15–22 kW standby units.
Will a 3,500 W generator run a refrigerator?
Yes, a typical household refrigerator runs on a few hundred watts and starts at up to about 2,200 W, well within 3,500 W. You could also run lights and a TV, but not a large heater at the same time.
Do I add the surge watts of every appliance?
No. Add all running watts, then add only the extra surge of the largest motor, since starting surges last only seconds and rarely overlap.
What is the difference between running and starting watts?
Running (rated) watts is what the generator can supply continuously; starting (peak) watts is what it can supply for a few seconds to start motors. Size your total load against the running figure.
How much bigger should a generator be than my load?
A 10–25% margin is typical. It allows for loads added later, altitude and heat derating, and keeps the engine from running flat out.
References
- Portable Generator Safety — US Consumer Product Safety Commission (CPSC)
- NFPA 70, National Electrical Code (Article 702, Optional Standby Systems) — National Fire Protection Association (NFPA)
About this calculator
- Built and reviewed by the Calculation Machine team · How we build and test calculators
- Last reviewed: October 24, 2026
- Report an error